INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 170.771 [21.8741], 1DC: 239.188 [33.6043], 2DC: 418.417 [25.0562], 3DC: 652.542 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 170.25 [16.142], 1DC: 217.896 [30.4674], 2DC: 347.5 [25.0823], 3DC: 540.021 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 170.229 [0.0571771], 1DC: 170.375 [0.0841329], 2DC: 170.604 [2.33369], 3DC: 175.958 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 171.625 [52.4072], 1DC: 292.292 [72.1974], 2DC: 541.479 [166.737], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 171.271 [40.8432], 1DC: 275.042 [79.6502], 2DC: 496.042 [240.354], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 172.25 [9.41833], 1DC: 192.688 [19.4168], 2DC: 237.271 [62.8611], 3DC: 387.208 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 171.854 [22.9346], 1DC: 219.75 [20.2264], 2DC: 292.792 [13.4557], 3DC: 425.375 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 174.062 [24.371], 1DC: 255.958 [17.0558], 2DC: 388.833 [10.1727], 3DC: 543.396 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 172.542 [35.3708], 1DC: 275.417 [26.0202], 2DC: 449 [13.3471], 3DC: 699.458 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 175.229 [44.9704], 1DC: 275.312 [72.1683], 2DC: 487.417 [221.955], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 173.25 [39.4444], 1DC: 321.583 [84.7475], 2DC: 639.542 [142.587], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 174.271 [48.6368], 1DC: 285.646 [63.2085], 2DC: 543.292 [128.804], 3DC: 1023 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 5 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 11 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved