INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 169.562 [16.8646], 1DC: 239.042 [28.0865], 2DC: 421.792 [22.9385], 3DC: 658.854 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 173.042 [16.5756], 1DC: 220.333 [26.7673], 2DC: 350.979 [22.6989], 3DC: 543.438 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 167.375 [0.166462], 1DC: 171.5 [0.82212], 2DC: 173.521 [1.0344], 3DC: 176 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 171.25 [44.0969], 1DC: 290.708 [67.9431], 2DC: 541.896 [164.406], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 171.354 [38.0256], 1DC: 275.854 [65.5258], 2DC: 497.75 [191.118], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 173.229 [9.9131], 1DC: 193.583 [20.4833], 2DC: 238.458 [63.8077], 3DC: 390.208 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 174.542 [20.0797], 1DC: 221.562 [15.591], 2DC: 293.875 [13.678], 3DC: 425.417 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 172.083 [18.4606], 1DC: 254.083 [20.4439], 2DC: 381.5 [10.1641], 3DC: 533.521 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 171.896 [29.9599], 1DC: 274.583 [24.1246], 2DC: 444.792 [13.1997], 3DC: 697.417 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 173.729 [41.9354], 1DC: 275.312 [67.5419], 2DC: 488.667 [211.261], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 174.438 [43.6077], 1DC: 321.604 [74.6447], 2DC: 640.25 [111.383], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 173.854 [42.7888], 1DC: 285.5 [77.0063], 2DC: 543.354 [184.115], 3DC: 1023 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 12 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 11 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved