INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 168.854 [16.021], 1DC: 238.562 [27.838], 2DC: 420.896 [22.4619], 3DC: 663.875 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 170.812 [15.5694], 1DC: 218.25 [21.7212], 2DC: 350.146 [20.6449], 3DC: 546 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 171.646 [0.171028], 1DC: 172.021 [1.22969], 2DC: 174.562 [1.08588], 3DC: 176.979 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 172.042 [41.1666], 1DC: 291.896 [60.4211], 2DC: 546.375 [134.839], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 171.771 [33.7474], 1DC: 276.479 [60.6037], 2DC: 500.979 [192.682], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 172.708 [9.22414], 1DC: 192.917 [19.24], 2DC: 237.958 [73.8369], 3DC: 392.062 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 173.208 [22.3125], 1DC: 219.396 [16.3448], 2DC: 292.354 [12.921], 3DC: 423.125 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 173.708 [19.9996], 1DC: 253.875 [17.202], 2DC: 382.812 [9.68528], 3DC: 531.542 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 171.75 [29.7877], 1DC: 273.229 [23.7008], 2DC: 443.979 [12.3924], 3DC: 690.833 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 175 [44.3706], 1DC: 273.083 [66.1569], 2DC: 484.646 [200.461], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 175 [40.0588], 1DC: 317.688 [62.1013], 2DC: 634.812 [90.4699], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 173.188 [46.9695], 1DC: 284.625 [61.1667], 2DC: 541.125 [130.662], 3DC: 1023 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 12 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 11 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved