INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 172.5 [20.6551], 1DC: 239.458 [25.0287], 2DC: 408.5 [19.295], 3DC: 631.979 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 173.562 [15.0512], 1DC: 219.5 [24.2976], 2DC: 345.354 [23.5111], 3DC: 529.604 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 173.333 [0.998897], 1DC: 194.583 [0.356828], 2DC: 209.208 [0.497762], 3DC: 246.208 INFO - Beginning fine timing calibration... WARN - WARNING: bmax - bmin > 3 ERROR - Cannot find the right bucket for PLT FED channel 0-1: Adjust = 8 ERROR - Cannot find the right bucket for PLT FED channel 0-2: Adjust = 7 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 1 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved