INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 169.167 [17.873], 1DC: 236.479 [25.6287], 2DC: 405.625 [21.2876], 3DC: 632.229 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 170.667 [14.4892], 1DC: 216.708 [21.4191], 2DC: 342.312 [19.9011], 3DC: 525.396 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 169.854 [0.747284], 1DC: 171.5 [1.23179], 2DC: 174.333 [1.37523], 3DC: 177.375 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 168.792 [52.4368], 1DC: 291.146 [76.9516], 2DC: 535 [192.515], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 169.333 [43.0295], 1DC: 274.854 [60.4236], 2DC: 487.417 [174.32], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 172.312 [10.0961], 1DC: 194.021 [19.2991], 2DC: 240.125 [58.9], 3DC: 389.938 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 173.562 [20.4636], 1DC: 225.188 [18.2991], 2DC: 306.25 [12.6575], 3DC: 445.375 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 172.729 [22.9735], 1DC: 263.812 [18.5506], 2DC: 407.875 [10.8399], 3DC: 578.708 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 169.021 [4.52664], 1DC: 282.354 [27.9363], 2DC: 460.333 [17.0426], 3DC: 723.833 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 175.75 [43.8711], 1DC: 281.479 [58.8492], 2DC: 490.771 [177.1], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 173.771 [53.6585], 1DC: 329.208 [78.1523], 2DC: 651.875 [108.17], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 174.979 [46.4569], 1DC: 289.938 [61.6888], 2DC: 552.25 [124.403], 3DC: 1023 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 11 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved