INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 167.083 [20.5317], 1DC: 231.396 [31.6482], 2DC: 398.562 [21.1828], 3DC: 617.979 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 167.896 [13.7522], 1DC: 213.188 [23.0306], 2DC: 335.229 [20.0172], 3DC: 517.979 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 166.771 [16.0761], 1DC: 207.146 [21.5144], 2DC: 283.5 [28.915], 3DC: 394.583 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 170.938 [53.0657], 1DC: 293.396 [80.4592], 2DC: 538.021 [193.587], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 170.146 [40.3225], 1DC: 275.271 [74.9529], 2DC: 490.667 [229.593], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 174.167 [9.20967], 1DC: 195.979 [18.6636], 2DC: 241.667 [52.2973], 3DC: 392.25 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 173.708 [21.3315], 1DC: 225.562 [17.5963], 2DC: 306.667 [11.1459], 3DC: 449.625 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 173.229 [23.1047], 1DC: 264.917 [17.4805], 2DC: 405.979 [10.7564], 3DC: 576.771 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 171.604 [37.1328], 1DC: 281.375 [29.5817], 2DC: 460.583 [14.8049], 3DC: 727.396 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 175.542 [43.2361], 1DC: 278.625 [69.2638], 2DC: 486.104 [207.56], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 173.792 [52.1368], 1DC: 328.229 [76.1265], 2DC: 651.771 [104.032], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 173.417 [38.0055], 1DC: 289.083 [63.9375], 2DC: 552.646 [135.184], 3DC: 1023 INFO - Beginning fine timing calibration... INFO - Timing calibration successful, all fastors are in bucket 11 INFO - Looks okay to me, writing params files to conf/ `conf/params_pltfed0.dat' -> `calib/params_pltfed0.dat' `conf/params_pltfed34.dat' -> `conf/params_pltfed0.dat' New settings saved in conf/params_pltfed0.dat and old settings saved in calib/params_pltfed0.dat. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved