INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 169.625 [19.4117], 1DC: 234.938 [22.7503], 2DC: 403.521 [19.5468], 3DC: 632.229 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 171.396 [14.2313], 1DC: 216.625 [23.3159], 2DC: 343.729 [19.9358], 3DC: 528.021 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 172.854 [10.9093], 1DC: 202.958 [10.2434], 2DC: 231.146 [7.61859], 3DC: 251.771 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 174.104 [55.1242], 1DC: 295.771 [69.8407], 2DC: 542.042 [153.751], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 172.667 [41.1972], 1DC: 277.542 [70.6896], 2DC: 493.625 [225.4], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 173.583 [9.37801], 1DC: 195.604 [19.3512], 2DC: 242.438 [65.1092], 3DC: 396.979 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 174.062 [22.4079], 1DC: 224.146 [15.0687], 2DC: 303.896 [10.559], 3DC: 445.479 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 172.354 [28.2561], 1DC: 260.75 [18.691], 2DC: 402.438 [9.47465], 3DC: 566.542 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 173.688 [33.0949], 1DC: 282.917 [27.2041], 2DC: 459.271 [14.7055], 3DC: 721.958 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 174.625 [38.6224], 1DC: 277.417 [64.8603], 2DC: 485.479 [206.655], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 174.104 [57.0529], 1DC: 327.771 [77.4897], 2DC: 651.667 [103.356], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 174.667 [45.7906], 1DC: 290.479 [60.6016], 2DC: 551.729 [125.243], 3DC: 1023 INFO - Beginning fine timing calibration... INFO - Timing calibration successful, all fastors are in bucket 11 INFO - Looks okay to me, writing params files to conf/ `conf/params_pltfed0.dat' -> `calib/params_pltfed0.dat' `conf/params_pltfed34.dat' -> `conf/params_pltfed0.dat' New settings saved in conf/params_pltfed0.dat and old settings saved in calib/params_pltfed0.dat. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved