INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 176.208 [20.6633], 1DC: 243.458 [25.6998], 2DC: 416.167 [19.0506], 3DC: 650.583 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 174.479 [14.4377], 1DC: 220.167 [23.8947], 2DC: 347.208 [22.1892], 3DC: 537.479 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 188.229 [5.41135], 1DC: 203.083 [5.48672], 2DC: 218.229 [4.27806], 3DC: 229.708 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 172.375 [50.4789], 1DC: 294.958 [74.7491], 2DC: 544.521 [172.413], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 172.438 [37.8287], 1DC: 277.25 [65.5441], 2DC: 497.542 [193.13], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 172.604 [9.90047], 1DC: 196.042 [19.5984], 2DC: 244.542 [57.0224], 3DC: 408.625 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 172.042 [17.8941], 1DC: 221.062 [16.075], 2DC: 299 [13.3385], 3DC: 437.104 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 170.542 [3.47642], 1DC: 258.75 [20.9551], 2DC: 395.479 [10.6177], 3DC: 561.125 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 174 [32.0978], 1DC: 280.833 [27.1354], 2DC: 457.896 [13.3247], 3DC: 715 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 173.938 [37.6172], 1DC: 275.333 [62.0961], 2DC: 484.625 [207.877], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 172.646 [48.6951], 1DC: 322.979 [79.6866], 2DC: 646.542 [108.109], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 172.833 [44.2765], 1DC: 287.625 [59.2343], 2DC: 549.292 [115.404], 3DC: 1023 INFO - Beginning fine timing calibration... INFO - Timing calibration successful, all fastors are in bucket 11 INFO - Looks okay to me, writing params files to conf/ `conf/params_pltfed0.dat' -> `calib/params_pltfed0.dat' `conf/params_pltfed34.dat' -> `conf/params_pltfed0.dat' New settings saved in conf/params_pltfed0.dat and old settings saved in calib/params_pltfed0.dat. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved