INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 181.438 [7.50858], 1DC: 216.125 [20.5167], 2DC: 311.479 [21.4012], 3DC: 439.417 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 160.583 [14.0688], 1DC: 191.542 [29.0634], 2DC: 275.458 [28.9402], 3DC: 403.208 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 127.188 [11.7851], 1DC: 147.729 [7.51356], 2DC: 162.625 [5.30355], 3DC: 173.833 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 160.979 [37.1604], 1DC: 234.062 [66.761], 2DC: 398.958 [63.1608], 3DC: 872.5 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 160.354 [20.2515], 1DC: 221.75 [38.9435], 2DC: 362.583 [103.403], 3DC: 876.583 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 163.125 [28.8911], 1DC: 223.5 [57.333], 2DC: 369.292 [162.336], 3DC: 912.667 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 159.521 [1.18069], 1DC: 187.354 [13.4503], 2DC: 236.479 [14.7668], 3DC: 356.396 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 164.729 [10.1232], 1DC: 205.729 [13.2986], 2DC: 269.771 [13.8031], 3DC: 409.979 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 166.646 [20.6257], 1DC: 216.062 [21.5505], 2DC: 304.562 [12.1384], 3DC: 433.917 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 168.667 [28.0742], 1DC: 234.312 [56.5715], 2DC: 388.938 [169.938], 3DC: 906.958 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 172.667 [22.8656], 1DC: 251.604 [53.8318], 2DC: 439.917 [88.4957], 3DC: 833.5 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 173.208 [15.3036], 1DC: 229.5 [28.5983], 2DC: 368.812 [65.6257], 3DC: 991.042 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 10 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved