INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 139.708 [14.858], 1DC: 180.479 [21.6814], 2DC: 291.333 [18.398], 3DC: 443.75 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 1023 [-nan], 1DC: 1023 [-nan], 2DC: 1023 [-nan], 3DC: 1023 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 142.812 [42.6236], 1DC: 245.562 [66.5606], 2DC: 480.146 [178.238], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 144.604 [40.4257], 1DC: 235.458 [64.978], 2DC: 443.521 [220.713], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 149.146 [41.3468], 1DC: 236.812 [73.3501], 2DC: 450.562 [232.949], 3DC: 1023 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 147.917 [15.6537], 1DC: 187.562 [16.5337], 2DC: 259.083 [15.8702], 3DC: 449.333 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 156.5 [18.1281], 1DC: 211.708 [15.2289], 2DC: 307.042 [15.6035], 3DC: 505.188 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 159.896 [28.4911], 1DC: 234.833 [25.2747], 2DC: 368.875 [12.5887], 3DC: 571.438 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 167.5 [31.7768], 1DC: 245.75 [64.11], 2DC: 430.583 [269.17], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 171.271 [34.7024], 1DC: 278.667 [63.4259], 2DC: 532.479 [141.604], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 176.104 [20.0474], 1DC: 263.021 [38.7931], 2DC: 469.729 [128.34], 3DC: 1023 INFO - Beginning fine timing calibration... WARN - WARNING: bmax - bmin > 3 ERROR - Cannot find the right bucket for PLT FED channel 0-3: Adjust = 10 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 1000 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 0 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 10 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved