INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 176.708 [8.51049], 1DC: 219.875 [18.5088], 2DC: 336.271 [21.0904], 3DC: 489.979 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 168.958 [16.8299], 1DC: 205.896 [32.0944], 2DC: 311.354 [30.2027], 3DC: 467.542 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 170.292 [0.189077], 1DC: 170.646 [0.675329], 2DC: 172 [0.769446], 3DC: 173.562 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 164.875 [34.853], 1DC: 267.458 [66.1782], 2DC: 503.396 [185.825], 3DC: 1023 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 166.562 [32.2779], 1DC: 258.792 [60.522], 2DC: 469.354 [218.783], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 167.792 [39.248], 1DC: 255.708 [78.4676], 2DC: 465.875 [283.702], 3DC: 1023 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 168.604 [14.6454], 1DC: 208.396 [14.4342], 2DC: 282.458 [16.342], 3DC: 474.125 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 172.396 [8.65957], 1DC: 228.75 [13.0796], 2DC: 332.021 [12.0962], 3DC: 522.438 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 169.312 [26.0784], 1DC: 243.292 [20.8861], 2DC: 376.292 [15.6603], 3DC: 576.292 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 172.729 [38.3736], 1DC: 249.625 [65.7526], 2DC: 430.646 [244.01], 3DC: 1023 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 174.271 [44.4324], 1DC: 281.042 [57.3605], 2DC: 533.771 [121.305], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 174.604 [38.8199], 1DC: 262.562 [51.1625], 2DC: 473.75 [147.129], 3DC: 1023 INFO - Beginning fine timing calibration... ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 7 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 11 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 10 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 10 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed34.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved