INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) INFO - Set up PLT FED interface #0, base address = 0x44000000, ID = 34 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 171.312 [15.3589], 1DC: 210.521 [21.1828], 2DC: 311.208 [18.6393], 3DC: 441.417 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 171.708 [9.84545], 1DC: 205.354 [19.8586], 2DC: 297 [19.2609], 3DC: 430.125 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 162.667 [17.4069], 1DC: 198.438 [31.166], 2DC: 265.208 [32.9822], 3DC: 352.854 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 171.729 [48.9227], 1DC: 280.125 [66.0267], 2DC: 498.062 [43.5832], 3DC: 1009.27 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 170.75 [38.5352], 1DC: 266.688 [66.2242], 2DC: 464.708 [227.151], 3DC: 1023 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 171.312 [40.491], 1DC: 265.5 [63.5109], 2DC: 470.354 [209.525], 3DC: 1023 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 172.312 [21.5877], 1DC: 224.75 [19.4357], 2DC: 308.833 [14.7795], 3DC: 456.188 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 174.083 [27.2286], 1DC: 253.812 [22.0506], 2DC: 379.417 [11.9455], 3DC: 529.979 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 171.771 [36.3498], 1DC: 268.229 [23.7878], 2DC: 423.5 [14.6222], 3DC: 655.542 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 175.396 [36.1685], 1DC: 258.167 [59.1681], 2DC: 429.333 [146.266], 3DC: 942.771 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 173.896 [36.37], 1DC: 293.521 [67.4796], 2DC: 546.625 [82.9053], 3DC: 1002.52 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 174.688 [31.3708], 1DC: 275.667 [54.7584], 2DC: 504.479 [154.123], 3DC: 1023 INFO - Beginning fine timing calibration... INFO - Timing calibration successful, all fastors are in bucket 11 INFO - Looks okay to me, writing params files to conf/ `conf/params_pltfed0.dat' -> `calib/params_pltfed0.dat' `conf/params_pltfed34.dat' -> `conf/params_pltfed0.dat' New settings saved in conf/params_pltfed0.dat and old settings saved in calib/params_pltfed0.dat. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved