INFO - Pixel FED TTCrx OK (PLL ready, dll ready, frame synced)
INFO - Set up Pixel FED interface #0, base address = 0x11000000, ID = 33
INFO - Writing old DACs to calib/
INFO - Beginning VcThr scan with VCal=250 VCalRange=0
INFO - Beginning VcThr scan for mFEC 7-1 Hub 5 ROC 0; current VcThr is 87
INFO - mFEC 7-1 Hub 5 ROC 0: Plateau is from VcThr = 55 to 125; picking 90
INFO - Beginning VcThr scan for mFEC 7-1 Hub 5 ROC 1; current VcThr is 94
WARN - Warning: hole in plateau at 71
INFO - mFEC 7-1 Hub 5 ROC 1: Plateau is from VcThr = 72 to 123; picking 98
INFO - Beginning VcThr scan for mFEC 7-1 Hub 5 ROC 2; current VcThr is 84
WARN - Warning: hole in plateau at 56
INFO - mFEC 7-1 Hub 5 ROC 2: Plateau is from VcThr = 57 to 121; picking 89
INFO - Beginning VcThr scan for mFEC 7-1 Hub 13 ROC 0; current VcThr is 102
INFO - mFEC 7-1 Hub 13 ROC 0: Plateau is from VcThr = 68 to 142; picking 105
INFO - Beginning VcThr scan for mFEC 7-1 Hub 13 ROC 1; current VcThr is 117
INFO - mFEC 7-1 Hub 13 ROC 1: Plateau is from VcThr = 76 to 164; picking 120
INFO - Beginning VcThr scan for mFEC 7-1 Hub 13 ROC 2; current VcThr is 112
INFO - mFEC 7-1 Hub 13 ROC 2: Plateau is from VcThr = 70 to 161; picking 117
INFO - Beginning VcThr scan for mFEC 7-1 Hub 21 ROC 0; current VcThr is 97
INFO - mFEC 7-1 Hub 21 ROC 0: Plateau is from VcThr = 66 to 134; picking 101
INFO - Beginning VcThr scan for mFEC 7-1 Hub 21 ROC 1; current VcThr is 104
WARN - Warning: hole in plateau at 71
INFO - mFEC 7-1 Hub 21 ROC 1: Plateau is from VcThr = 72 to 143; picking 107
INFO - Beginning VcThr scan for mFEC 7-1 Hub 21 ROC 2; current VcThr is 86
INFO - mFEC 7-1 Hub 21 ROC 2: Plateau is from VcThr = 64 to 114; picking 89
INFO - Beginning VcThr scan for mFEC 7-1 Hub 29 ROC 0; current VcThr is 78
WARN - Warning: hole in plateau at 56
INFO - mFEC 7-1 Hub 29 ROC 0: Plateau is from VcThr = 57 to 101; picking 79
INFO - Beginning VcThr scan for mFEC 7-1 Hub 29 ROC 1; current VcThr is 105
INFO - mFEC 7-1 Hub 29 ROC 1: Plateau is from VcThr = 67 to 149; picking 109
INFO - Beginning VcThr scan for mFEC 7-1 Hub 29 ROC 2; current VcThr is 99
INFO - mFEC 7-1 Hub 29 ROC 2: Plateau is from VcThr = 63 to 142; picking 102
INFO - Writing new DACs to conf/
INFO - CalibrateVcThr complete.