INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 WARN - PLT FED #0 warning: base address in config file (0x44000000) does not match address in FED params data file (0x44) INFO - Set up PLT FED interface #0, base address = 0x44, ID = 32 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 174.708 [26.0191], 1DC: 227.896 [49.9713], 2DC: 354.312 [126.059], 3DC: 729.479 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 200.583 [24.9395], 1DC: 251.458 [46.5448], 2DC: 363 [167.058], 3DC: 831.396 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 163.083 [18.169], 1DC: 199 [20.9921], 2DC: 249.5 [184.965], 3DC: 782.979 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 207.833 [31.2133], 1DC: 303.062 [49.4699], 2DC: 552.312 [108.025], 3DC: 1023 INFO - Threshold 0 for 0-4 manually adjusted to 230 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 179.188 [33.1718], 1DC: 249.521 [44.6361], 2DC: 427.667 [39.5161], 3DC: 956.083 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 125.938 [32.5003], 1DC: 199.729 [43.9437], 2DC: 391.271 [28.8209], 3DC: 989.812 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 186.229 [36.9752], 1DC: 278.438 [61.1882], 2DC: 504.667 [161.746], 3DC: 1023 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 215.958 [49.7444], 1DC: 357.104 [66.2693], 2DC: 707.896 [66.4619], 3DC: 1023 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 219.354 [45.7731], 1DC: 343.271 [66.5944], 2DC: 672.75 [77.2971], 3DC: 1023 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 196.417 [32.1308], 1DC: 275.812 [32.7929], 2DC: 469.167 [21.9983], 3DC: 945.604 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 202.875 [18.7952], 1DC: 286.604 [46.2836], 2DC: 532.562 [120.095], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - Beginning fine timing calibration... WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 1000 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed32.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved