INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 WARN - PLT FED #0 warning: base address in config file (0x44000000) does not match address in FED params data file (0x44) INFO - Set up PLT FED interface #0, base address = 0x44, ID = 32 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 184.396 [21.2784], 1DC: 236.312 [51.6139], 2DC: 362.792 [135.178], 3DC: 741 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 174.125 [22.1582], 1DC: 224.083 [38.6462], 2DC: 334.5 [141.656], 3DC: 803.854 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 105.542 [21.0009], 1DC: 140.625 [22.873], 2DC: 189.792 [187.392], 3DC: 729.521 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 131.792 [35.7141], 1DC: 223.646 [51.0806], 2DC: 467.479 [126.251], 3DC: 1023 INFO - Threshold 0 for 0-4 manually adjusted to 230 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 208.625 [33.455], 1DC: 278.021 [43.179], 2DC: 454.333 [30.9804], 3DC: 967.521 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 150.083 [27.0138], 1DC: 221.062 [34.8724], 2DC: 407.771 [30.3316], 3DC: 991.917 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 218.688 [39.071], 1DC: 309.333 [64.5063], 2DC: 534.5 [155.473], 3DC: 1023 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 145.083 [56.9774], 1DC: 281.542 [77.3354], 2DC: 623.771 [99.7755], 3DC: 1023 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 256.917 [49.5537], 1DC: 380.625 [69.1122], 2DC: 711.5 [71.7448], 3DC: 1023 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 132.208 [27.435], 1DC: 208.021 [29.5567], 2DC: 394.354 [23.4637], 3DC: 859 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 231.625 [37.9735], 1DC: 313.875 [72.4031], 2DC: 554.917 [156.646], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - Beginning fine timing calibration... WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 1000 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed32.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved