INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 WARN - PLT FED #0 warning: base address in config file (0x44000000) does not match address in FED params data file (0x44) INFO - Set up PLT FED interface #0, base address = 0x44, ID = 32 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 172.542 [18.4109], 1DC: 218.083 [40.1896], 2DC: 336.833 [131.372], 3DC: 731.375 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 206.167 [9.97838], 1DC: 253.479 [22.9488], 2DC: 362.458 [95.0377], 3DC: 891.167 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 134.646 [27.7934], 1DC: 205.125 [60.5138], 2DC: 391.271 [263.826], 3DC: 1023 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 170.229 [28.4009], 1DC: 255.729 [51.3514], 2DC: 479.75 [141.272], 3DC: 1023 INFO - Threshold 0 for 0-4 manually adjusted to 230 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 156.354 [28.9598], 1DC: 216.062 [30.953], 2DC: 368.312 [23.0434], 3DC: 855.021 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 152.062 [23.3174], 1DC: 210.854 [31.1838], 2DC: 363.667 [24.4607], 3DC: 882.562 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 152.188 [38.9885], 1DC: 233.771 [54.2406], 2DC: 435.062 [177.302], 3DC: 1023 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 174.417 [58.1097], 1DC: 298.292 [69.6429], 2DC: 620.396 [92.5464], 3DC: 1023 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 203.958 [45.0595], 1DC: 317.938 [66.5118], 2DC: 631.979 [88.9144], 3DC: 1023 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 167.188 [27.7376], 1DC: 231.667 [28.042], 2DC: 388.083 [21.2288], 3DC: 815.125 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 180.458 [21.601], 1DC: 254.479 [46.087], 2DC: 480.354 [129.054], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - Beginning fine timing calibration... WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 1000 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed32.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved