INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 WARN - PLT FED #0 warning: base address in config file (0x44000000) does not match address in FED params data file (0x44) INFO - Set up PLT FED interface #0, base address = 0x44, ID = 32 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 155.75 [23.1273], 1DC: 197.375 [46.2847], 2DC: 311 [167.628], 3DC: 721.542 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 211.896 [21.9293], 1DC: 256.875 [42.7023], 2DC: 363.354 [173.596], 3DC: 933.5 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 110.646 [27.3876], 1DC: 176.688 [46.506], 2DC: 357.479 [191.445], 3DC: 1023 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 147.333 [29.1749], 1DC: 224.708 [36.0326], 2DC: 429.479 [112.767], 3DC: 1023 INFO - Threshold 0 for 0-4 manually adjusted to 230 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 141 [20.8508], 1DC: 193.896 [26.9563], 2DC: 329.438 [17.7502], 3DC: 788.938 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 113.312 [19.8659], 1DC: 164.521 [23.3666], 2DC: 295.875 [20.4999], 3DC: 782.312 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 120.583 [28.954], 1DC: 195.021 [51.2968], 2DC: 379.958 [206.464], 3DC: 1023 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 147.375 [42.5472], 1DC: 263.104 [62.4658], 2DC: 568.688 [103.117], 3DC: 1023 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 182.188 [35.2523], 1DC: 289.708 [52.9447], 2DC: 591.562 [82.2938], 3DC: 1023 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 134.375 [20.1991], 1DC: 189.396 [20.5486], 2DC: 322.188 [21.1762], 3DC: 720.438 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 251.833 [15.8727], 1DC: 321.854 [37.436], 2DC: 542.854 [101.105], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - Beginning fine timing calibration... WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 1000 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed32.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved