INFO - PLT FED TTCrx OK (PLL ready, dll ready, frame synced) WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 WARN - PLT FED #0 warning: base address in config file (0x44000000) does not match address in FED params data file (0x44) INFO - Set up PLT FED interface #0, base address = 0x44, ID = 32 INFO - Output will be stored in this file: /home/2017ColdBox/cmsplt/interface/calib/pltlevelsfast_calibration_output.txt WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 INFO - PLTFED channel 0-1 (mFec 7-1 hubAddress 5 roc 1) INFO - Levels and [separations]: BLMax: 164.875 [22.199], 1DC: 204.917 [52.3943], 2DC: 317.146 [180.056], 3DC: 738.375 INFO - PLTFED channel 0-2 (mFec 7-1 hubAddress 5 roc 2) INFO - Levels and [separations]: BLMax: 175.667 [9.38371], 1DC: 218.083 [20.703], 2DC: 323.062 [97.3291], 3DC: 906.083 INFO - PLTFED channel 0-3 (mFec 7-1 hubAddress 5 roc 3) INFO - Levels and [separations]: BLMax: 127.229 [29.9892], 1DC: 191.562 [55.3973], 2DC: 371.396 [231.774], 3DC: 1023 INFO - PLTFED channel 0-4 (mFec 7-1 hubAddress 13 roc 1) INFO - Levels and [separations]: BLMax: 168.958 [19.269], 1DC: 243.396 [27.2598], 2DC: 444.792 [86.0131], 3DC: 1023 INFO - Threshold 0 for 0-4 manually adjusted to 230 INFO - PLTFED channel 0-5 (mFec 7-1 hubAddress 13 roc 2) INFO - Levels and [separations]: BLMax: 167.5 [24.4908], 1DC: 217 [27.945], 2DC: 344.208 [23.7639], 3DC: 804.229 INFO - PLTFED channel 0-6 (mFec 7-1 hubAddress 13 roc 3) INFO - Levels and [separations]: BLMax: 133.042 [21.3852], 1DC: 179.292 [23.3275], 2DC: 301.5 [19.6556], 3DC: 777.708 INFO - PLTFED channel 0-10 (mFec 7-1 hubAddress 21 roc 1) INFO - Levels and [separations]: BLMax: 126.917 [31.4474], 1DC: 197.583 [59.416], 2DC: 379.292 [254.822], 3DC: 1023 INFO - PLTFED channel 0-11 (mFec 7-1 hubAddress 21 roc 2) INFO - Levels and [separations]: BLMax: 153.167 [48.0342], 1DC: 266.125 [74.2406], 2DC: 568.792 [124.266], 3DC: 1023 INFO - PLTFED channel 0-12 (mFec 7-1 hubAddress 21 roc 3) INFO - Levels and [separations]: BLMax: 191.229 [46.8122], 1DC: 295.188 [60.4585], 2DC: 596.833 [90.6547], 3DC: 1023 INFO - PLTFED channel 0-13 (mFec 7-1 hubAddress 29 roc 1) INFO - Levels and [separations]: BLMax: 140.958 [20.6486], 1DC: 193.458 [23.1616], 2DC: 321.479 [18.7062], 3DC: 712.125 INFO - PLTFED channel 0-14 (mFec 7-1 hubAddress 29 roc 2) INFO - Levels and [separations]: BLMax: 166.75 [23.435], 1DC: 232.917 [51.1134], 2DC: 444.792 [159.209], 3DC: 1023 INFO - PLTFED channel 0-15 (mFec 7-1 hubAddress 29 roc 3) INFO - Levels and [separations]: BLMax: 0 [-nan], 1DC: 0 [-nan], 2DC: 0 [-nan], 3DC: 0 INFO - Beginning fine timing calibration... WARN - soft FEDID = 32 doesn't match hard board FEDID = 34 ERROR - Error: ot all fastors are landing in the same bucket. Either that or there are no fastors!!! INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 1: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 2: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 3: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 4: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 5: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 6: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 10: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 11: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 12: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 13: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 14: 9 INFO - MaxBucket after adjustment for pltFedId 0 pltFedChannel 15: 1000 WARN - Something looks not quite right so: writing params files to calib/ WARN - If you want these settings you have to copy them by hand ERROR: couldn't find conf/params_pltfed32.dat; perhaps the calibration failed? Files will not be moved. ERROR: pltfed1_id is not set in calibration-configuration.conf; file will not be moved